top of page

Contact: 1-800-600-700

רקע דקורטיבי לכותרת

Glossary of Terms

Remedix care - bringing health to your home

The terms are presented in order A-B

Infuser - disposable infusion pump suitable for home care

An infuser is a disposable pump for intravenous or subcutaneous infusion. The pump includes an external container and a balloon inside, into which the pharmacist inserts the treatment solution in the prescription. In fact, the content of the infuser is based on a personal prescription that includes the dose of the drug and the infusion rate according to the patient's personal data. The infusion rate is a consequence of the degree of elasticity of the balloon. The infuser shell is rigid and adapted to the comfort of the patient at home.‎

The infuser pump allows mobility at home and normal conduct in everyday life.‎

The pump has a unique structure that prevents the solution from leaking out and blocks the entry of pollutants inside. In order for the pump to work optimally and allow a correct flow rate, the pump top must be attached to the body as much as possible. From the moment the cap is removed, the medicine flows into the cannula according to the rate set in the prescription.‎

Infuser - frequently asked questions and answers

Is it possible to sleep with the pump?‎

Yes. It is advisable to place it on a nearby dresser and not on the bed.‎

Is it possible to shower with the pump?‎

Yes. The infuser must be wrapped in a bag to prevent water from entering. You can also place the pump on a surface outside the shower.‎

How do you know that the pump has finished its activity?‎

In the hard container is a balloon with the drug solution inside. The balloon comes full. From the moment the cap of the infuser tube is removed, the medicine begins to flow out, and at the same time the medicine balloon slowly shrinks. The flow rate is slow and complies with the doctor's instructions. At the end of the infusion, the volume of the balloon will be reduced to the size of a finger.‎

What affects the rate of drug flow?‎

High heat and exposure to the sun accelerate the rate of the balloon's emptying. It is recommended not to stay in direct sunlight. On the other hand, cold slows down the rate of emptying the balloon. And in any case, it is important to verify from time to time that the connection to the catheter is correct, and that the flow of the medicine is progressing.‎

Infuser

Hyperemesis gravidarum is a condition of multiple nausea and/or vomiting in ‏‏pregnancy.‎‏‏‏‏

Many women suffer from the phenomenon of nausea with or without vomiting during pregnancy, and the severity of the phenomenon varies from woman to woman. The nausea usually starts between weeks 5-6 of pregnancy, it reaches its peak around week 9, and will usually pass by weeks 16-18.‎

The common symptoms of hyperemesis gravidarum are nausea that lasts for several hours during the day and vomiting with a frequency of three or more times a day. These symptoms interfere with daily life and normal routine.‏

The causes of hyperemesis gravidarum are mostly unknown, but there are several hypotheses for the causes of the phenomenon, including a slowdown in the functioning of the digestive system, high secretion of hormones during ‏‎pregnancy and psychological factors‎.‏‎‎‎‎

Multiple vomiting can cause fluid loss and may lead to dehydration. A condition of hyperemesis gravidarum requires medical treatment aimed at controlling the vomiting avoid dehydreation and provide hydration, when needed.‎

In severe cases, it is possible to treat hyperemesis gravidarum, under a doctor's order, also at home, with intravenous drug ‏therapy and with IV hydration.‎‏‏

Hyperemesis Gravidarum - Multiple vomiting and nausea in pregnancy

IV= Intravenous

TPN = Total Parenteral Nutrition

This term refers to a bag used for intravenous feeding. The bag contains dividers that create three sections. The three sections contain various nutritional components (amino acids, dextrose, lipid emulsion and various electrolytes) in a fixed composition.‎

Before using the bag, partitions are opened by rolling the bag. The rolling allows the mixing of the contents of the three sections, to obtain a homogeneous infusion solution. The 3CB bag provides all the required ‏‏‏.‎nutrients, except vitamins and trace elements‎‎‏‎

Three Chamber Bag: 3CB

bottom of page